Nichrome A and Nichrome C Industrial heating wires
Nichrome heater wire is of two types Nichrome A and Nichrome C. Nichrome A is made of NiCr alloy containing 80% nickel and 20% chromium. It has lower temperature coefficient of resistance as compare to Nichrome C. Nichrome A has service temperature up to 1150oC or 2100oF.
Nichrome C heater wire is made of NiCr alloy containing 60% nickel and 16% chromium and remaining iron 24%. Nichrome C has service temperature up to 1000oC or 1850oF. It has higher coefficient of electric resistance as compared to Nichrome A.
Both Nichrome A and Nichrome C offer outstanding corrosion resistance.
Nichrome C is a significant material in applications that need high resistance in a controlled space. In the heating and technical applications, Nichrome A is widely employed. Nichrome A and Nichrome C wires are made in large or small spool sizes, coils or straightened and cut to length.
Nichrome A
Wire Gauge | Inches | mm | Ohms/Foot | Feet/Pound |
000 | 0.410 inches | 10.414 mm | 0.003867 Ohms / Foot | 2.077 Feet / Pound |
00 | 0.365 inches | 9.271 mm | 0.004879 Ohms / Foot | 2.621 Feet / Pound |
0 | 0.325 inches | 8.255 mm | 0.006154 Ohms / Foot | 3.305 Feet / Pound |
1 | 0.289 inches | 7.341 mm | 0.007782 Ohms / Foot | 4.180 Feet / Pound |
2 | 0.258 inches | 6.553 mm | 0.009765 Ohms / Foot | 5.245 Feet / Pound |
3 | 0.229 inches | 5.817 mm | 0.01240 Ohms / Foot | 6.658 Feet / Pound |
4 | 0.204 inches | 5.182 mm | 0.01562 Ohms / Foot | 8.390 Feet / Pound |
5 | 0.182 inches | 4.623 mm | 0.01962 Ohms / Foot | 10.54 Feet / Pound |
6 | 0.162 inches | 4.115 mm | 0.02477 Ohms / Foot | 13.30 Feet / Pound |
7 | 0.114 inches | 3.658 mm | 0.03135 Ohms / Foot | 16.84 Feet / Pound |
8 | 0.128 inches | 3.251 mm | 0.03967 Ohms / Foot | 21.31 Feet / Pound |
9 | 0.114 inches | 2.896 mm | 0.05002 Ohms/Foot | 26.87 Feet / Pound |
10 | 0.102 inches | 2.591 mm | 0.06248 Ohms / Foot | 33.56 Feet / Pound |
11 | 0.091 inches | 2.311 mm | 0.07849 Ohms / Foot | 42.16 Feet / Pound |
12 | 0.081 inches | 2.057 mm | 0.09907 Ohms / Foot | 53.21 Feet / Pound |
13 | 0.072 inches | 1.829 mm | 0.01254 Ohms / Foot | 67.35 Feet / Pound |
14 | 0.064 inches | 1.626 mm | 0.01587 Ohms / Foot | 85.24 Feet / Pound |
15 | 0.057 inches | 1.448 mm | 0.2001 Ohms / Foot | 107.50 Feet / Pound |
16 | 0.051 inches | 1.295 mm | 0.2499 Ohms / Foot | 134.20 Feet / Pound |
17 | 0.045 inches | 1.143 mm | 0.3210 Ohms / Foot | 172.40 Feet / Pound |
18 | 0.040 inches | 1.016 mm | 0.4063 Ohms / Foot | 218.20 Feet / Pound |
19 | 0.0360 inches | 0.9140 mm | 0.5015 Ohms / Foot | 269.40 Feet / Pound |
20 | 0.0320 inches | 0.8130 mm | 0.6348 Ohms / Foot | 341.00 Feet / Pound |
21 | 0.0285 inches | 0.7239 mm | 0.8002 Ohms / Foot | 429.80 Feet / Pound |
22 | 0.0253 inches | 0.6426 mm | 1.015 Ohms / Foot | 545.50 Feet / Pound |
23 | 0.0226 inches | 0.5740 mm | 0.273 Ohms / Foot | 683.60 Feet / Pound |
24 | 0.0201 inches | 0.5105 mm | 0.609 Ohms / Foot | 864.20 Feet / Pound |
25 | 0.0179 inches | 0.4547 mm | 2.029 Ohms / Foot | 1090 Feet / Pound |
26 | 0.0159 inches | 0.4039 mm | 2.571 Ohms / Foot | 1381 Feet / Pound |
27 | 0.0142 inches | 0.3607 mm | 3.224 Ohms / Foot | 1731 Feet / Pound |
28 | 0.0126 inches | 0.3200 mm | 4.094 Ohms / Foot | 2199 Feet / Pound |
29 | 0.0113 inches | 0.2870 mm | 5.090 Ohms / Foot | 2734 Feet / Pound |
30 | 0.0100 inches | 0.2540 mm | 6.500 Ohms / Foot | 3491 Feet / Pound |
31 | 0.0089 inches | 0.2261 mm | 8.206 Ohms / Foot | 4408 Feet / Pound |
32 | 0.0080 inches | 0.2032 mm | 10.160 Ohms / Foot | 5455 Feet / Pound |
33 | 0.0071 inches | 0.1803 mm | 12.890 Ohms / Foot | 5626 Feet / Pound |
34 | 0.0063 inches | 0.1600 mm | 16.380 Ohms / Foot | 8797 Feet / Pound |
35 | 0.0056 inches | 0.1422 mm | 20.730 Ohms / Foot | 11130 Feet / Pound |
36 | 0.0050 inches | 0.1270 mm | 26.000 Ohms / Foot | 13970 Feet / Pound |
37 | 0.0045 inches | 0.113 mm | 32.100 Ohms / Foot | 17240 Feet / Pound |
38 | 0.0040 inches | 0.1016 mm | 40.630 Ohms / Foot | 21820 Feet / Pound |
39 | 0.0035 inches | 0.0889 mm | 53.060 Ohms / Foot | 28500 Feet / Pound |
40 | 0.00310 inches | 0.0787 mm | 67.640 Ohms / Foot | 36330 Feet / Pound |
41 | 0.00275 inches | 0.0699 mm | 85.950 Ohms / Foot | 46170 Feet / Pound |
42 | 0.00250 inches | 0.0635 mm | 104.000 Ohms / Foot | 55860 Feet / Pound |
43 | 0.00225 inches | 0.0672 mm | 128.400 Ohms / Foot | 68970 Feet / Pound |
44 | 0.00200 inches | 0.0508 mm | 162.500 Ohms / Foot | 87280 Feet / Pound |
45 | 0.00175 inches | 0.0445 mm | 212.00 Ohms / Foot | 114000 Feet / Pound |
46 | 0.00150 inches | 0.0381 mm | 288.900 Ohms / Foot | 155200 Feet / Pound |
Nichrome C
Wire Gauge | Inches | mm | Ohms/Foot | Feet/Pound |
000 | 0.410 Inches | 10.414 mm | 0.004015 Ohms / Foot | 2.119 Feet / Pound |
00 | 0.365 Inches | 9.271 mm | 0.005067 Ohms / Foot | 2.673 Feet / Pound |
0 | 0.325 Inches | 8.255 mm | 0.006391 Ohms / Foot | 3.372 Feet / Pound |
1 | 0.289 Inches | 7.341 mm | 0.008082 Ohms / Foot | 4.264 Feet / Pound |
2 | 0.258 Inches | 6.553 mm | 0.01014 Ohms / Foot | 5.351 Feet / Pound |
3 | 0.229 Inches | 5.817 mm | 0.01287 Ohms / Foot | 6.792 Feet / Pound |
4 | 0.204 Inches | 5.182 mm | 0.01622 Ohms / Foot | 8.559 Feet / Pound |
5 | 0.182 Inches | 4.623 mm | 0.02038 Ohms / Foot | 10.75 Feet / Pound |
6 | 0.162 Inches | 4.115 mm | 0.02572 Ohms / Foot | 13.57 Feet / Pound |
7 | 0.114 Inches | 3.658 mm | 0.03255 Ohms / Foot | 17.18 Feet / Pound |
8 | 0.128 Inches | 3.251 mm | 0.04120 Ohms / Foot | 21.74 Feet / Pound |
9 | 0.114 Inches | 2.896 mm | 0.05194 Ohms / Foot | 17.41 Feet / Pound |
10 | 0.102 Inches | 2.591 mm | 0.06488 Ohms / Foot | 34.23 Feet / Pound |
11 | 0.091 Inches | 2.311 mm | 0.08151 Ohms / Foot | 43.01 Feet / Pound |
12 | 0.081 Inches | 2.057 mm | 0.1029 Ohms / Foot | 54.29 Feet / Pound |
13 | 0.072 Inches | 1.829 mm | 0.1302 Ohms / Foot | 68.71 Feet / Pound |
14 | 0.064 Inches | 1.626 mm | 0.1648 Ohms / Foot | 86.96 Feet / Pound |
15 | 0.057 Inches | 1.448 mm | 0.2078 Ohms / Foot | 109.6 Feet / Pound |
16 | 0.051 Inches | 1.295 mm | 0.2595 Ohms / Foot | 136.9 Feet / Pound |
17 | 0.045 Inches | 1.143 mm | 0.3333 Ohms / Foot | 175.9 Feet / Pound |
18 | 0.040 Inches | 1.016 mm | 0.4219 Ohms / Foot | 222.6 Feet / Pound |
19 | 0.0360 Inches | 0.9140 mm | 0.5208 Ohms / Foot | 274.8 Feet / Pound |
20 | 0.0320 Inches | 0.8130 mm | 0.6592 Ohms / Foot | 347.8 Feet / Pound |
21 | 0.0285 Inches | 0.7239 mm | 0.831 Ohms / Foot | 438.5 Feet / Pound |
22 | 0.0253 Inches | 0.6426 mm | 10055 Ohms / Foot | 556.4 Feet / Pound |
23 | 0.0226 Inches | 0.5740 mm | 1.322 Ohms / Foot | 697.3 Feet / Pound |
24 | 0.0201 Inches | 0.5105 mm | 1.671 Ohms / Foot | 881.6 Feet / Pound |
25 | 0.0179 Inches | 0.4547 mm | 2.107 Ohms / Foot | 1112 Feet / Pound |
26 | 0.0159 Inches | 0.4039 mm | 2.670 Ohms / Foot | 1409 Feet / Pound |
27 | 0.0142 Inches | 0.3607 mm | 3.348 Ohms / Foot | 1766 Feet / Pound |
28 | 0.0126 Inches | 0.3200 mm | 4.252 Ohms / Foot | 2243 Feet / Pound |
29 | 0.0113 Inches | 0.2870 mm | 5.286 Ohms / Foot | 2289 Feet / Pound |
30 | 0.0100 Inches | 0.2540 mm | 6.750 Ohms / Foot | 2562 Feet / Pound |
31 | 0.0089 Inches | 0.2261 mm | 8.522 Ohms / Foot | 4497 Feet / Pound |
32 | 0.0080 Inches | 0.2032 mm | 10.55 Ohms / Foot | 5565 Feet / Pound |
33 | 0.0071 Inches | 0.1803 mm | 13.39 Ohms / Foot | 7065 Feet / Pound |
34 | 0.0063 Inches | 0.1600 mm | 17.01 Ohms / Foot | 8974 Feet / Pound |
35 | 0.0056 Inches | 0.1422 mm | 21.52 Ohms / Foot | 11360 Feet / Pound |
36 | 0.0050 Inches | 0.1270 mm | 27.00 Ohms / Foot | 14250 Feet / Pound |
37 | 0.0045 Inches | 0.113 mm | 33.33 Ohms / Foot | 17590 Feet / Pound |
38 | 0.0040 Inches | 0.1016 mm | 42.19 Ohms / Foot | 22260 Feet / Pound |
39 | 0.0035 Inches | 0.0889 mm | 55.10 Ohms / Foot | 29080 Feet / Pound |
40 | 0.00310 Inches | 0.0787 mm | 70.24 Ohms / Foot | 37060 Feet / Pound |
41 | 0.00275 Inches | 0.0699 mm | 89.26 Ohms / Foot | 47100 Feet / Pound |
42 | 0.00250 Inches | 0.0635 mm | 108.00 Ohms / Foot | 55990 Feet / Pound |
43 | 0.00225 Inches | 0.0672 mm | 133.30 Ohms / Foot | 70350 Feet / Pound |
44 | 0.00200 Inches | 0.0508 mm | 168.80 Ohms / Foot | 89040 Feet / Pound |
45 | 0.00175 Inches | 0.0445 mm | 220.40 Ohms / Foot | 116300 Feet / Pound |
46 | 0.00150 Inches | 0.0381 mm | 300.00 Ohms / Foot | 158300 Feet / Pound |